Construction Guides Terms of Service
BUILD STAGE
Section I Handover and Certificates Required
GUIDELINE
Certificates Required for Sale
Architects Ancillary Certificate
Engineers Certificates required
Specialist Designer Certificates
Certificates Required for Sale
Share
[]{#RANGE!B2:M119 .anchor}
Project: **
*Date: * **
Submitted by: Ryan & Associates (Assigned Certifier)
BCMS Ref:
Commencement Ref: **
**Houses 1, 2, 3, 4
SUPPORTING DOCUMENTATION
Works Document Type File Name/No. Documentation Uploaded
Assigned Certifier Certificates of Completion 01. CCC_Houses 1, 2, 3, 4 Certificates of Compliance on Completion - Houses 1 - 4 Uploaded BCMS
Architect Ancillary Certificates 02A. Ancillary Certs Ancillary Certificates of Compliance: Design - Houses 1 - 4
Ancillary Certificates of Compliance: Inspection - Houses 1 - 4
Compliance with Planning Docs 02B. Compliance House 1 Opinion on Compliance with Planning - Houses 1
Compliance with Planning Docs 02B. Compliance House 2 Opinion on Compliance with Planning - Houses 2
Compliance with Planning Docs 02B. Compliance House 3 Opinion on Compliance with Planning - Houses 3
Compliance with Planning Docs 02B. Compliance House 4 Opinion on Compliance with Planning - Houses 4
Final Construction Drawings 02C. Architect Drawings
M+E_Consultant Ancillary Certificates 03A. Ancilary Certs Mec and Elec Ancillary Certificates of Compliance: Design Uploaded
Ancillary Certificates of Compliance: Inspection - Houses 1 - 4
Ancillary Certificates of Compliance: Completion - Houses 1-4
Electrical Completion Certificates 03B. Mec and Elec Docs Completion Certs - Houses 1-4
Cerficate of Design of Smoke/Heat Alarm Systems Certificates - Houses 1-4
Cerficate of Installation & Commissioning of Smoke/Heat Alarm Systems Certificates - Houses 1-4
BER's 03C. BER and Part Lpdf BER Certs & Reports - Houses 1-4
Part L Reports Part L Reports - Houses 1-4
M+E Final Construction Drawings 03D. Mec and Elec Drawings House 1 MVHR Layout
House Type A MVHR Layout
MVHR Schematic
Communications Schematic
Electrical Schematic.
Fire Alarm Schematic
Heat Pump Wiring Schematic
House 1 Lighting Layout
House 1 Power Layout
House 4 Lighting Layout
House 4 Power Layout
House Type A Lighting Layout
House Type A Power Layout
MVHR Wiring Schematic
Security Schematic
Heating & Plumbing Final Construction Drawings 04. Heating and Plumbing Domestic Water Schematic Uploaded
Heating Schematic
House 1 Domestic Water Layout
House 1 Drainage Layout
House 1 Heating Layout
House Type A Domestic Water Layout
House Type A Drainage Layout
House Type A Heating Layout
Heat Recovery HRV Commissioning Reports 05. Heat Recovery HRV Commissioning Report, Checklist & Calibration Uploaded
Air-Tightness Test Documentation 06. Air-Tightness Air Tightness Test Data Uploaded
Sound Insulation Testing Test Documentation 07. Sound Insulation Sound Insulation Test Data (1 test per 20 houses) Uploaded
Civil_Structural Ancillary Certificates 08A_Ancillary Certs Ancillary Certificate of Compliance: Design Uploaded
Ancillary Certificate of Compliance: Inspection
Ancillary Certificate of Compliance: Completion
Civil Drawings_Final Construction 08B_Civil Dwg
Structural Drawings_Final Construction 08C_Struct Dwg
Specification 08D_Specifications
Specifications Documentation General Specifications
Structural Specifications
Civil Specifications
Heating & Plumbing Specifications
Electrical Specifications
Inspection Plans Documentation Structural & Civil
Architect
Mechanical & Electrical
Assigned Certifier
**The documents below will not be uploaded to the BCMS system due to the volume of documents but should be provided. **
Builder / Sub-Contractors Ancillary Certificates of Completion File Name/No. Documentation
Ground Works - **
Manhole Inspections
Testing Reports
Ancillary Certificate_Ground Works
**Foundations/Formwork
Ancillary Certificates_Foundations_if relevant Ancillary Certificates
Screed
Ancillary Certtificates_ground and first floor level Ancillary Certtificates_ground and first floor level
Blocklaying
Ancillary Certificates_Blocklaying Ancillary Certtificates_ground and first floor level
Cavity Wall Insulation
Ancillary Certificates_Cavity Wall Insulation Ancillary Certificates ground and first floor level
Carpentry/ Partitions
Ancillary Certificates_Carpentry/partition Ancillary Certificates
Steel & Stone
Steel & Stone Certs Ancillary Certificates
External Windows & Doors
Ancillary Certificates _Windows & Doors_ground and first floor level Ancillary Certificates
Plastering
Ancillary Certificates_Plastering_ground and first floor level Ancillary Certificates
Heating & Plumbing
Ancillary Certificates_Plumbing_ground and first floor level Ancillary Certificates
Gas Installations (where relevant)
Ancillary Certificates_Installation of Gas Tanks_ground and first floor level Installation of Gas Tanks
Electrical Works **
Ancillary Certificates_Electrical Works Ancillary Certificates ground and first floor level.
Electical Tests & Commissions ET101 completion certificate, FDAS design, installation and commissioning certificates and testing records
**Ceramic Tiling
Ancillary Certificates_Tiling_ground and first floor level Ancillary Certificates ground and first floor level
Kitchens
Ancillary Certificates_Kitchens_Houses 30-44 Ancillary Certificates Houses
Stairs
Ancillary Certificates_Stairs Ancillary Certificates Houses
Painting
Ancillary Certificates_Painting Ancillary Certificates Houses
Fire Detection & Alarm System
Included within Electrical Testing & Commissioning Documents Ancillary Certificates Houses ground and first floor level
Fire Stopping
Ancillary certificate - Fire stopping Ancillary Certificates (all product data sheets supplied)
Fire Doors
Ancillary certificate - Fire Doors Ancillary Certificates for installation of fire doorsall fire door certs to be supplied.
Join us at Housebuild!